    • Commodity name: Hydraulic fire equipment SQD150-2.5 multi-use fire pump adapter
    • Commodity ID: SQD150-2.5

    1. product introduction

    The fire pump adapter is a special fire-fighting equipment for the high-rise building water supply supporting the fire pump. It mainly solves the problem of insufficient water pressure in high-rise buildings and ensures the fire water of high-rise buildings. The fire pump adapter is based onCode for fire protection of tall buildingsThe fire fighting facilities designed for high-rise buildings are designed to supply water to the fire fighting water supply system in the building through the interface of the adapter to pressurize the water supply system, so that the indoor fire fighting devices in the building can have sufficient pressure water source for other fire fighting devices to extinguish fires on different floors, thus solving the fire fighting difficulties in high-rise buildings after fire or the low water pressure of the indoor fire hydrant water supply system in the building, resulting in insufficient or no water supply, etc.

     

    Ground water pump adapter and multi-purpose water pump adapter; bolt body and interface are higher than the ground, the target is obvious, easy to use, underground water pump adapter; installed under the ground does not occupy the ground position, it is not easy to find damage. Especially suitable for cold areas.

      Technical parameters of 2. products

     Product Name         Model specifications   Nominal working pressure       Strength test pressure   Nominal outlet diameter   Import Nominal Size Fire interface type

                                                      MPa               MPa             mm             mm

    Above-ground firefighting       SQS100-1.6            1.6                         2.4                       100                     65*65               KWS65

    Water pump adapter       SQS150-1.6            1.6                         2.4                       150                     80*80               KWS80  

    Underground fire fighting       SQX100-1.6           1.6                         2.4                       100                     65*65               KWS65

    Water pump adapter       SQX150-1.6           1.6                         2.4                       150                     80*80               KWS80

    wall type fire fighting       SQB100-1.6           1.6                         2.4                       100                     65*65               KWS65

    Water pump adapter       SQB150-1.6           1.6                         2.4                       150                     80*80               KWS80 

    Multi-use fire protection       SQD100-1.6           1.6                         2.4                       100                     65*65               KWS65

    Water pump adapter       SQD150-1.6           1.6                         2.4                       150                    80*80                KWS80

    energy-saving fire fighting       SQS100-1.6A         1.6                         2.4                       100                     65*65               KWS65(self-contained gate valve

    Water pump adapter       SQS150-1.6A         1.6                         2.4                       150                     80*80               KWS80      Check Valve

                                SQX100-1.6A        1.6                         2.4                       100                     65*65               KWS65      Safety valve

                                SQX150-1.6A        1.6                         2.4                       150                     80*80               KWS80       function)

     

    3. maintenance

    1. The installation shall be carried out in accordance with the specified requirements. The fire water supply pipeline using the fire pump adapter should be separated from the domestic water pipeline to prevent pollution of domestic water (such as unconditional separation, it should also be guaranteed to be disconnected during use). The connection of each component and the connection with the underground pipeline shall be sealed to prevent leakage. After installation, the pipeline should be level, and the gate valve and drain valve should be opened flexibly. A hydrostatic test with a pressure of 1.6MPa was also performed. The drain valve and the overflow port of the safety valve shall be connected with other sewer ditches so as to release the residual water after use.

    2. During operation, the manhole cover shall be opened first and the drain valve shall be closed. Then unscrew the stuffy cover of the external thread fixing interface, and connect the water hose to supply water from the fire truck. After use, open the drain valve to cover the manhole cover. Remove the hose and screw the cover of the fixed interface.

     

    3. The fire pump adapter must be managed by a fixed person and maintained regularly to ensure normal operation during use. The aging seal should be replaced in time. To prevent arbitrary buried pressure, ring occupied fire pump adapter.

    水力消防器材SQD150-2.5多用式消防水泵接合器

    Key words:
    • 消防器材
    • 消防设备
    • 福建消防器材
    • 福建消防设备

1. product introduction

The fire pump adapter is a special fire-fighting equipment for the high-rise building water supply supporting the fire pump. It mainly solves the problem of insufficient water pressure in high-rise buildings and ensures the fire water of high-rise buildings. The fire pump adapter is based onCode for fire protection of tall buildingsThe fire fighting facilities designed for high-rise buildings are designed to supply water to the fire fighting water supply system in the building through the interface of the adapter to pressurize the water supply system, so that the indoor fire fighting devices in the building can have sufficient pressure water source for other fire fighting devices to extinguish fires on different floors, thus solving the fire fighting difficulties in high-rise buildings after fire or the low water pressure of the indoor fire hydrant water supply system in the building, resulting in insufficient or no water supply, etc.

 

Ground water pump adapter and multi-purpose water pump adapter; bolt body and interface are higher than the ground, the target is obvious, easy to use, underground water pump adapter; installed under the ground does not occupy the ground position, it is not easy to find damage. Especially suitable for cold areas.

  Technical parameters of 2. products

 Product Name         Model specifications   Nominal working pressure       Strength test pressure   Nominal outlet diameter   Import Nominal Size Fire interface type

                                                  MPa               MPa             mm             mm

Above-ground firefighting       SQS100-1.6            1.6                         2.4                       100                     65*65               KWS65

Water pump adapter       SQS150-1.6            1.6                         2.4                       150                     80*80               KWS80  

Underground fire fighting       SQX100-1.6           1.6                         2.4                       100                     65*65               KWS65

Water pump adapter       SQX150-1.6           1.6                         2.4                       150                     80*80               KWS80

wall type fire fighting       SQB100-1.6           1.6                         2.4                       100                     65*65               KWS65

Water pump adapter       SQB150-1.6           1.6                         2.4                       150                     80*80               KWS80 

Multi-use fire protection       SQD100-1.6           1.6                         2.4                       100                     65*65               KWS65

Water pump adapter       SQD150-1.6           1.6                         2.4                       150                    80*80                KWS80

energy-saving fire fighting       SQS100-1.6A         1.6                         2.4                       100                     65*65               KWS65(self-contained gate valve

Water pump adapter       SQS150-1.6A         1.6                         2.4                       150                     80*80               KWS80      Check Valve

                            SQX100-1.6A        1.6                         2.4                       100                     65*65               KWS65      Safety valve

                            SQX150-1.6A        1.6                         2.4                       150                     80*80               KWS80       function)

 

3. maintenance

1. The installation shall be carried out in accordance with the specified requirements. The fire water supply pipeline using the fire pump adapter should be separated from the domestic water pipeline to prevent pollution of domestic water (such as unconditional separation, it should also be guaranteed to be disconnected during use). The connection of each component and the connection with the underground pipeline shall be sealed to prevent leakage. After installation, the pipeline should be level, and the gate valve and drain valve should be opened flexibly. A hydrostatic test with a pressure of 1.6MPa was also performed. The drain valve and the overflow port of the safety valve shall be connected with other sewer ditches so as to release the residual water after use.

2. During operation, the manhole cover shall be opened first and the drain valve shall be closed. Then unscrew the stuffy cover of the external thread fixing interface, and connect the water hose to supply water from the fire truck. After use, open the drain valve to cover the manhole cover. Remove the hose and screw the cover of the fixed interface.

 

3. The fire pump adapter must be managed by a fixed person and maintained regularly to ensure normal operation during use. The aging seal should be replaced in time. To prevent arbitrary buried pressure, ring occupied fire pump adapter.