Product classification


undefined
+
  • undefined

Click image to enlarge

Deluge alarm valve

ZSFM200

Retail price

$ 0

Market price

$ 0


Weight

0

Quantity
-
+

Stock

0

隐藏域元素占位

Classification:

Key words:

Alarm valve

  • Product Description
    • Commodity name: Deluge alarm valve
    • Commodity ID: ZSFM200

    1. product introduction

    The deluge fire alarm valve is a one-way valve that is started by wet, dry and electrical control, so that water can automatically flow into the water spray system in one direction and alarm at the same time. Widely used in deluge systems, pre-action systems, water mist systems and water curtain systems. The deluge system is mainly composed of deluge valve, automatic start control system pipe network, open nozzle and water supply system.

         ZSFGThe lever type deluge alarm valve is a kind of one-way valve which is opened by electric, mechanical or other methods, so that water can automatically flow into the water spray system in one direction and alarm at the same time. Under the control of the on-site fire detection system in the protection zone, when a fire occurs, the fire detection system acts to link the deluge alarm valve to open, the water from the water supply pipeline flows into the protection zone pipe network on the system side, the nozzle starts to spray water, and at the same time sends out sound and light alarm signals to achieve the purpose of alarm, fire control and fire extinguishing. Widely used in wet, dry rain alarm fire extinguishing system, can also be with the foam system to form a foam sprinkler system, used to put out the explosion of liquid fire.

    The lever type deluge alarm valve produced by our company hasZSFG100,ZSFG150,ZSFG200And other types of specifications.

      2. working principle

        The pressure in the diaphragm chamber of the deluge valve is used to push the lever, and then the valve flap is held by the lever to achieve sealing. When opening, the pressure in the diaphragm chamber is released, and the valve flap is opened by the pressure on the water supply side.

      3. technical parameters

     

      Technical parameters

    Model specifications

    Nominal diameter(mm)

    Rated work(MPa)

    Strength test(MPa)

    Sealing test(MPa)

    Friction(MPa)

    Start-up time(s)

    ZSFG100

    100

    1.2

    4.8

    2.4

    0.07

    15

    ZSFG150

    150

    ZSFG200

    200

    Key words:
    • 消防器材
    • 消防设备
    • 福建消防器材
    • 福建消防设备

1. product introduction

The deluge fire alarm valve is a one-way valve that is started by wet, dry and electrical control, so that water can automatically flow into the water spray system in one direction and alarm at the same time. Widely used in deluge systems, pre-action systems, water mist systems and water curtain systems. The deluge system is mainly composed of deluge valve, automatic start control system pipe network, open nozzle and water supply system.

     ZSFGThe lever type deluge alarm valve is a kind of one-way valve which is opened by electric, mechanical or other methods, so that water can automatically flow into the water spray system in one direction and alarm at the same time. Under the control of the on-site fire detection system in the protection zone, when a fire occurs, the fire detection system acts to link the deluge alarm valve to open, the water from the water supply pipeline flows into the protection zone pipe network on the system side, the nozzle starts to spray water, and at the same time sends out sound and light alarm signals to achieve the purpose of alarm, fire control and fire extinguishing. Widely used in wet, dry rain alarm fire extinguishing system, can also be with the foam system to form a foam sprinkler system, used to put out the explosion of liquid fire.

The lever type deluge alarm valve produced by our company hasZSFG100,ZSFG150,ZSFG200And other types of specifications.

  2. working principle

    The pressure in the diaphragm chamber of the deluge valve is used to push the lever, and then the valve flap is held by the lever to achieve sealing. When opening, the pressure in the diaphragm chamber is released, and the valve flap is opened by the pressure on the water supply side.

  3. technical parameters

 

  Technical parameters

Model specifications

Nominal diameter(mm)

Rated work(MPa)

Strength test(MPa)

Sealing test(MPa)

Friction(MPa)

Start-up time(s)

ZSFG100

100

1.2

4.8

2.4

0.07

15

ZSFG150

150

ZSFG200

200

e654278a-aeda-4f80-8df4-4b5a0bf0af45.jpg